Patient Monitor Accessory Compatibility Matrix
Quick Answer: This cross-reference matrix helps BMETs identify the correct replacement accessory for any patient monitor brand. Use it as follows:
- Find your brand in the left column of the parameter-specific table (SpO2, ECG, NIBP, IBP, Temperature)
- Match the module or connector type — especially critical for SpO2 (FAST vs. OxiMax vs. TruSignal) and IBP (Abbott, Edwards, Utah, BD, B.Braun)
- Click the MedLinket part number to view the product page with ISO 13485 / FDA 510(k) specifications
Covers Philips, GE, Mindray, Dräger, Nihon Kohden, and 10+ additional brands.
Most-Replaced Monitor Accessories Across All Brands



This page answers "which accessory fits which monitor" — the compatibility cross-reference. For electrical pinout details and wiring diagrams, see our SpO2 connector pinout reference. For visual connector identification, see our ECG cable connector types guide. For NIBP fitting dimensions, see our NIBP hose connector specifications. For IBP cable wiring, see our IBP cable pinout reference. For brand-specific service details, see our Philips & GE service guide and Mindray technical resources.
1. How to Use This Matrix

Each table below is organized by parameter (SpO2, ECG, NIBP, IBP, Temperature). Find your monitor brand in the left column, then read across to find compatible accessory part numbers with direct links to the product page. The tables focus on the most commonly replaced accessories — for the full catalog, visit the linked product collections.
2. SpO2 Sensor Compatibility Matrix
SpO2 compatibility depends on the SpO2 technology module installed, not just the monitor brand. Identify the module first — for technology identification help, see our SpO2 connector pinout reference.
| Monitor Brand | SpO2 Technology | Adult Finger Clip | Pediatric Clip | Neonatal Wrap | Adult Soft/Y-Type | Ear Clip |
|---|---|---|---|---|---|---|
| Philips IntelliVue (MX / MP / X3) | ||||||
| Philips (FAST module) | Philips FAST | M1191BL | M1192A | M1196A | M1191T | M1194A |
| Philips (Nellcor module) | Nellcor OxiMax | DS-100A | D-YSP | M1193T | D-YS | — |
| GE Healthcare (CARESCAPE / DASH) | ||||||
| GE (TruSignal module) | GE TruSignal | TS-SA4-GE | Ped clip | — | TS-E4-GE | — |
| GE (M-Tech module) | GE Proprietary | Adult clip | Ped M-Tech | — | — | — |
| Mindray (BeneVision / iPM / iMEC) | ||||||
| Mindray (native) | Mindray | 512FLH | — | Neonatal | Adult soft | Ear clip |
| Nihon Kohden (BSM / Life Scope) | ||||||
| Nihon Kohden | NK Proprietary | P205A | — | — | — | — |
| Nonin | ||||||
| Nonin | Nonin | 8000AA | 8000AP | Neo wrap | 8000SL | 8000Q2 |
| Biolight / Comen / Edan | ||||||
| Biolight | Biolight | Adult soft | Ped soft | — | — | — |
| Comen | Comen | Adult soft | — | — | — | — |
| Edan | Edan | Adult clip | Ped clip | Neo wrap | Adult soft | — |
Full SpO2 catalog: direct-connect sensors · short sensors · adapter cables · disposable sensors. For SpO2 error troubleshooting, see our error codes guide.


3. ECG Cable & Leadwire Compatibility Matrix
ECG compatibility depends on the trunk cable connector at the monitor end and the leadwire termination type (snap, grabber, banana). For connector visual identification, see our ECG cable connector types guide.
| Monitor Brand | Trunk Connector | 3-Lead Trunk | 5-Lead Trunk | 3-Lead Leadwires | 5-Lead Leadwires |
|---|---|---|---|---|---|
| Philips IntelliVue | 12-pin round | M1669A | M1668A | M1603A | M1671A |
| GE Marquette | 11-pin Marquette | 2106306-001 | 2017003-001 | 2021141-001 | 5-Lead grab |
| Mindray | Mindray 12-pin | EA6231A | EA6252A | Integrated direct-connect cables (trunk + leadwires in one) | |
| Nihon Kohden | NK proprietary | 3-Lead grab | 5-Lead grab | JC-906P trunk + separate leadwires | |
| Dräger | Dräger proprietary | — | MP03401 | — | |
| AAMI 6-Pin | 6-pin standard | 3-Lead grab | 5-Lead grab | Integrated direct-connect | |
Full ECG catalog: direct-connect ECG cables · trunk cables · telemetry leadwires · disposable electrodes.

MedLinket compatible accessories for Philips, GE, Mindray, Dräger, and Nihon Kohden — ISO 13485 certified with verified connector compatibility.
Philips GE Mindray Dräger Nihon Kohden
4. NIBP Hose & Cuff Compatibility Matrix
NIBP hose connectors are brand-specific and non-interchangeable. For fitting dimensions and connector type details, see our NIBP hose connector specifications. For troubleshooting NIBP errors, see our NIBP measurement errors guide.
| Monitor Brand | Connector Type | Adult Hose | Neonatal Hose | Reusable Adult Cuff | Disposable Adult Cuff |
|---|---|---|---|---|---|
| Philips | Quick-connect bayonet | M1599B | M1596B | M1574A | M4575B |
| GE | Dina-Click | 2087389-002 | 2017009-001 | Critikon | Dina-Click |
| Mindray | Mindray screw | 6200-30-09688 | 6200-30-11560 | Universal cuff with Mindray hose | Universal cuff with Mindray hose |
| Dräger | Quick-bayonet | Dräger adult | 2870298 | MP00915 | — |
| Nihon Kohden | SubMiniature | YN-901P | YN920P | NK adult cuff | SubMin disp |
| Welch Allyn | Various | Dina-Click | Neo luer | Universal cuff with WA hose | — |
Full NIBP catalog: NIBP hoses · reusable cuffs · adult disposable cuffs · neonatal disposable cuffs · connectors.


5. IBP Cable Compatibility Matrix
IBP cables have a brand-specific monitor end and a transducer-standard patient end. For cable pinout and signal details, see our IBP cable pinout reference. For troubleshooting, see our IBP transducer troubleshooting guide.
| Monitor Brand | Abbott/Medex | Edwards | Utah | BD/Ohmeda | B.Braun |
|---|---|---|---|---|---|
| Philips | 42661-27 | 896083021 | 650-206 | 684081 | M1634A |
| GE | 2021196-001 | 2021197-003 | 700078-001 | 684102 | GE B.Braun |
| Mindray | 001C-30-70759 | 0010-21-12179 | 650-206M | 001C-30-70757 | Mindray B.Braun |
| Dräger | MS22535 | MS22147 | MS22534 | MS22148 | Dräger B.Braun |
| Nihon Kohden | NK Abbott | JP-902P | NK Utah | JP-900P | NK B.Braun |
| Biolight | Abbott 4-pin | Edwards 4-pin | Utah 4-pin | BD 4-pin | B.Braun 4-pin |
Full IBP catalog: IBP cables · adapter cables · disposable transducers.

6. Temperature Probe Compatibility Matrix
Most current monitors use YSI 400 series thermistors. For a detailed comparison of YSI 400 vs 700, see our YSI 400 vs 700 temperature probe comparison. For troubleshooting, see our temperature probe error guide.
| Monitor Brand | YSI Series | Adapter Cable | Adult Skin | Adult Esoph/Rectal | Pediatric Skin |
|---|---|---|---|---|---|
| Philips | YSI 400 | 21082A | 21078A | 21075A | 21076A |
| GE | YSI 400 | 2016998-001 | GE skin | GE esoph | GE ped |
| Mindray | YSI 400 | MR420B | MR401 | MR401B | Ped skin |
| Dräger | YSI 400 | YSI 400 adapter | 4329822 | 4329848 | Ped skin |
| Nihon Kohden | YSI 400 | NK-specific connector | Use YSI standard probes with NK adapter cable | ||
| YSI Standard | YSI 400 | Brand-specific adapter | 409B | Esoph/rectal | Ped skin |
Full temperature catalog: reusable probes · disposable probes · adapter cables · infant incubator probes.
7. Adapter Cable Cross-Reference
SpO2 adapter cables are the most commonly needed adapter type — they sit between the monitor's SpO2 module and the sensor. For adapter cable signal routing details, see our SpO2 connector pinout reference.
| Monitor Brand | SpO2 Adapter Cable(s) | IBP Adapter Cable(s) | Temp Adapter Cable(s) |
|---|---|---|---|
| Philips | M1943A, M1940A, 989803148221, M1900B | 42661-14 | 21082A, 5020411A |
| GE | 2021406-001, TS-G3, TS-N3 | 2021197-001, 2005772-001 | 2016998-001, 2021701-001 |
| Mindray | 0010-20-42710, 115-020768-00, 115-023135-00 | 001C-30-70758 | MR420B |
| Nihon Kohden | JL-900P, JL-650P, JL-302T | — | NK-specific connector (integrated) |
| Masimo (cross-brand) | M-LNC-10 (2525), 0012-00-1653 | — | — |
| Nellcor (cross-brand) | DEC-8, DOC-10 | — | 502-0410 |
MedLinket's cross-brand compatible accessories are ISO 13485 certified with FDA 510(k) clearances. Browse by brand or by parameter to find your exact match.
All Accessories Browse by BrandFrequently Asked Questions
Can I use the same SpO2 sensor on both Philips and GE monitors?
Not directly — Philips FAST and GE TruSignal use different technologies. However, if both monitors have the same optional SpO2 module (e.g., both have Nellcor OxiMax modules), you can use the same sensor family with brand-specific adapter cables — for example, the Nellcor DS-100A compatible sensor works across any Nellcor module regardless of monitor brand. Always match the sensor to the installed module, not the monitor brand. For technology identification, see our SpO2 connector pinout reference.
Are NIBP cuffs interchangeable between monitor brands?
The cuffs themselves are often brand-independent — the brand-specific component is the hose connector. Use the correct hose (such as the Mindray 6200-30-09688 NIBP hose for BeneVision/iPM/iMEC) with the right connector for your brand, then attach any compatible cuff. See our NIBP hose connector specifications for connector type details by brand.
How do I find the right replacement accessory for my monitor model?
Use the compatibility tables above — find your brand and model, then follow the product links. For electrical connector verification, see the linked parameter-specific guides. For brand-specific service details, see our Philips & GE guide or Mindray guide.
Do ECG cables use the same connector across all Philips IntelliVue models?
Yes, all IntelliVue monitors (MX, MP, X3) use the same 12-pin round trunk cable connector — the Philips M1669A 3-lead trunk cable and M1668A 5-lead trunk cable cover the entire IntelliVue fleet with one set. SureSigns and Efficia may differ — always verify by model. See our ECG connector identification guide.
Can I use a Mindray temperature probe on a Philips monitor with an adapter?
Not directly — adapter cables are brand-specific. However, if both use YSI 400 thermistors (most current models do), you can use the same YSI 400 reusable probe with different brand-specific adapter cables — for example, the YSI 409B universal skin probe connects to either brand through the appropriate adapter. See our YSI 400 vs 700 comparison for thermistor compatibility.
What does "technology-locked" mean for SpO2 compatibility?
Technology-locked means the SpO2 module only accepts sensors from one technology family. A Masimo SET module rejects Nellcor or Philips FAST sensors with an "incompatible sensor" error. The lock is in the digital handshake, not just the connector. Match the sensor technology to the installed module. For evaluation criteria when sourcing compatible sensors, see our third-party evaluation framework.
Related BMET Resources
- Return to BMET Resource Hub
- SpO2 connector pinout reference — Electrical wiring diagrams by technology
- ECG cable connector types identification — Visual connector guide
- NIBP hose connector specifications — Fitting dimensions by brand
- IBP cable pinout and signal specifications
- YSI 400 vs 700 temperature probe comparison
- Medical cable specifications
- Philips & GE patient monitor service guide
- Mindray patient monitor technical resources
- Patient monitor error codes troubleshooting
- NIBP measurement errors troubleshooting
- Temperature probe error troubleshooting
- IBP transducer troubleshooting
- Patient monitor PM checklist
- Cable inspection and testing methods
- Calibration requirements
- Documentation and compliance
- How to evaluate third-party accessories
- OEM vs compatible accessories
- Vendor qualification checklist
- BMET cost-saving strategies